Specifying GRP
Guidance – not structural design
This guide gives quick initial guidance. Answers, texts and load tables are based on standard conditions and do not replace structural design or verification in your project. We accept no responsibility for errors in the information or for how it is interpreted and used – that responsibility lies with the client and their structural engineer. Need an exact answer? Send us your drawings or project details and we will review them. Read more in Technical disclaimer.
Text generator
The text updates as you make your choices. Values in [ ] are filled in for the project.
Products in the text
Surface
Resin
The manufacturer's standard for this product.
Unit: m²
Your text
Supplier: Byggkomposit Sverige AB, Swedish supplier of Dura Composites products. Manufacturer: d² Dura Grating Standard Mesh by Dura Composites, or equivalent meeting all requirements below. Moulded grating of glass reinforced plastic (GRP) with load-bearing capacity in both directions. Depth 38 mm. Mesh 31 mm, open area 66%. Self-weight no more than 13.2 kg/m². Resin: orthophthalic polyester. Surface: gritted anti-slip surface. Colour: dark grey. Fire classification Bfl-s1 to EN 13501-1. The anti-slip surface shall retain at least 95% of its slip resistance after one million footfalls, verified by testing. An Environmental Product Declaration (EPD) to EN 15804 shall be provided. Warranty: at least 25 years. Fixing: fixings in stainless steel to the manufacturer's instructions. Quantity: [state] m². Quotation and technical data: byggkomposit.se
Always check load, span and fire requirements against the project conditions. We are happy to review the text.
Resin
Orthophthalic and isophthalic polyester are standard. Vinyl ester is made on request.
| Resin | Choose when | Supply |
|---|---|---|
| Orthophthalic polyester | Moulded grating, Dura Slab and anti-slip products – most indoor and outdoor environments | Standard |
| Isophthalic polyester | Profiles, handrails and ladders – and grating where the chemical table requires it | Standard |
| Phenolic resin | Requirements for low smoke and low toxic fume emissions, for example tunnels and offshore | Stock: d² Dura Phenolic Grating, Dark Russet |
| Vinyl ester | Chemicals that orthophthalic and isophthalic polyester cannot withstand | On request |
Where chemicals are present, check chemical, concentration and temperature in the chemical resistance table. More about the resins in GRP resin types.
Fire classification
The fire classification to EN 13501-1 applies to the product – not to the fire resistance of the complete structure, for example R30.
| Product | Fire classification | Standard |
|---|---|---|
| Dura Deck Inspire (porcelain) | A1 – non-combustible | EN 13501-1 |
| Dura Deck Aluminium 18 and 27 mm | A2fl-s1 and A2-s1,d0 | EN 13501-1, tested by a UKAS-accredited laboratory |
| d² Dura Grating Standard Mesh, Mini Mesh 30–55 mm, Solid Top and Rectangular Mesh | Bfl-s1 | EN 13501-1, flooring |
| d² Dura Profile | Bfl-s1 in the fire-rated version, on request | EN 13501-1 |
| Dura Handrail | Class 2 (surface spread of flame) | BS 476 Part 7 – no Euroclass stated |
| d² Dura Phenolic Grating | Class 0 and BS 6853 | British standards – no Euroclass stated |
BS EN 13501-1 on Dura's pages is the British edition of EN 13501-1 – the same standard as SS-EN 13501-1 in Sweden. BS 476 and BS 6853 are British tests that cannot be translated into a Euroclass.
The difference between fire classification and R30 is explained in GRP fire classification.
Loads
Maximum clear span in mm at 5 kN/m² uniformly distributed load and deflection no more than L/200. The values are for guidance and must be verified in the project.
| Grating | Depth | Span |
|---|---|---|
| Standard Mesh | 26 mm | 510 |
| Standard Mesh | 38 mm | 780 |
| Standard Mesh | 50 mm | 970 |
| Mini Mesh | 23 mm | 450 |
| Mini Mesh | 35 mm | 710 |
| Mini Mesh | 45 mm | 880 |
| Mini Mesh | 55 mm | 1,110 |
| Solid Top | 29 mm | 710 |
| Solid Top | 41 mm | 890 |
| Solid Top | 53 mm | 1,240 |
Spans in both directions
Moulded grating carries load equally in both directions. Pultruded grating and Slab span in one direction – show the span direction on the drawing.
Other load cases
Point loads, other deflection limits and the full table are in the load tables.
Trench covers
d² Dura Grating Rectangular Mesh: load class B125 to EN 124, span no more than 630 mm.
Design
How to work out load and span: Calculating load and span.
Good to know
Non-combustible decking
Dura Deck Inspire is class A1 and Dura Deck Aluminium A2-s1,d0 – the two highest Euroclasses.
Colour
Dark grey is in stock. d² Dura Phenolic Grating is in stock in Dark Russet, panel 3660 × 1220 mm. Yellow, green and blue on request, depending on the product.
Surface and slip resistance
A gritted anti-slip surface is standard. It retains 95% of its slip resistance after one million footfalls to BS 7976. Read more in Anti-slip GRP grating.
Panels and cutting
Grating is supplied in standard panels, for example 3660 × 1220 mm, and cut on site. Cut edges are sealed as described in the installation instructions.
Fixing
Fixings in stainless steel, selected for grating depth and support structure. Specify acid-resistant stainless steel (A4) for saltwater and chemicals.
Electrical safety
GRP does not conduct electricity and is non-magnetic – often worth stating as a requirement for switchgear and railway projects.
Environmental data
EPD to EN 15804. Registration in Byggvarubedömningen is in progress.
Minimum order
Panels and profiles in vinyl ester, and some panels in isophthalic polyester, may be subject to a minimum order quantity. Ask us early in the project and we will check what applies.
Products and documentation
Images, dimensions and item numbers are on each product page.
- d² Dura Grating Standard MeshGrating
- d² Dura Grating Mini MeshGrating
- d² Dura Grating Micro MeshGrating
- d² Dura Grating Rectangular MeshGrating
- d² Dura Solid TopGrating
- d² Dura Phenolic GratingGrating
- d² Dura Pultruded GratingGrating
- d² Dura SlabFloor panels
- d² Dura ProfileProfiles, handrails and ladders
- Dura Handrail (GRP handrail)Profiles, handrails and ladders
- Dura Safety LaddersProfiles, handrails and ladders
- Fixings for GRP gratingProfiles, handrails and ladders
- d² Dura Grating Standard Concave 13 mmFencing and screening
- GRP fencing with d² panelsFencing and screening
- d² Dura Stair TreadStairs and anti-slip
- Dura Stair Tread CoverStairs and anti-slip
- Dura Tread anti-slip sheetStairs and anti-slip
- Dura Tread stair nosingStairs and anti-slip
- Dura TrackGloStairs and anti-slip
- Dura Deck Aluminium 18 mm Free-DrainBalcony and terrace decking
- Dura Deck Aluminium 18 mm Positive-DrainBalcony and terrace decking
- Dura Deck Aluminium 27 mm Positive-DrainBalcony and terrace decking
- d² Dura QuickspanBalcony and terrace decking
- Dura Deck Inspire (porcelain)Balcony and terrace decking
Technical documentation
- Chemical resistance149 chemicals, orthophthalic and isophthalic polyester
- Load and performance dataSpans and deflection
- GRP fire classificationEN 13501-1 and R30
- GRP resin typesProperties of each resin
- InstallationCutting, cut edges, fixing
- BIM objects on NBS SourceDura's objects in Revit and IFC. Our own models are coming to this site.
- Technical disclaimerWhat the data applies to
Frequently asked questions
What should a GRP specification text include?
Product and manufacturer, material and resin, depth or size, surface, colour, fire classification and fixing. Load and span are stated if they are not already shown on the drawing.
What fire classification does GRP grating have?
d² Dura Grating Standard Mesh, Mini Mesh 30–55 mm, Solid Top and Rectangular Mesh are classified Bfl-s1 to EN 13501-1, the flooring class. The classification applies to the product, not to the fire resistance of the complete structure.
Which resin should be stated on the drawing?
Orthophthalic polyester is standard for moulded grating and Dura Slab, isophthalic polyester for profiles, handrails and ladders. Where chemicals are present, the resin is chosen from the chemical resistance table. Vinyl ester is made on request.
What does BS mean in BS EN 13501-1?
BS EN 13501-1 is the British edition of the European standard EN 13501-1. In Sweden the same standard is called SS-EN 13501-1. BS 476 and BS 6853, on the other hand, are British tests that do not correspond to a Euroclass.
Need project-specific text or a load calculation?